Identity and sourcing requirements.
Key technical specifications
Ordering-code highlights reviewed against official manufacturer documentation.
- Function / range
- Digital absolute barometric pressure sensor, 300 hPa to 1,250 hPa · I2C and SPI interfaces with FIFO and an oversampling measurement engine (Table 1)
- Accuracy / consumption
- Relative accuracy ±0.03 hPa typical (700 hPa to 1,100 hPa, +25 °C to +40 °C); absolute accuracy ±0.5 hPa typical (300 hPa to 1,100 hPa, 0 °C to +65 °C); current consumption 3.2 µA typical at 1 Hz, pressure and temperature on (Table 1)
- Order code / package
- Single orderable identified by Bosch technical reference code 0 273 017 023 · 10-pin metal-lid LGA, 2.0 mm × 2.0 mm × 0.75 mm (maximum height 0.8 mm), tape and reel (ordering/marking section)
- Operating temperature
- −40 °C to +85 °C · operating temperature range